b.
Trim at least 20 mm of insulation from the end of the cable.
Fig. 5.49: Removing insulation
Fig. 5.50: Removed insulation
c.
Twist the braid forming the cable shielding together and wrap around the cable so that 2-3 loops
are next to each other at the end of the insulation. Separate individual pairs of conductors, remove
the aluminium shielding from them, cut it off, and separate individual conductors. Cut off the two
additional twisted pairs from the thinner wire in the middle (not seen on these images).
Fig. 5.51: Twisted shielding
Fig. 5.52: Removing aluminium conductor
shielding
d.
Prepare individual pairs according to the pinout sticker attached to the connector (T568B) and
unwind the two pairs for the bottom part of the connector. Take care not to confuse white conductors
from individual pairs.
Fig. 5.53: Separated pairs of conductors
Fig. 5.54: Lower two pairs ready for inserting