Replacing an Existing Wall Plate
Remove the two screws used to mount the existing wall
plate. Once these screws are removed, carefully pull the wall
plate far enough from the wall to reach the connections on
the back of the wall plate. The back of the wall plate should
look similar to one of the wall plates below.
Models before 2010
1
= Power
2
= Ground
3
= Antenna
4
= Cable
5
= TV2
6
= TV1*
Models after 2010
*Some wall plates have a
cable coming out of the
front of the plate. This is
TV1.
Disconnect the 12 VDC power ( ) from the existing wall
plate, and mark the cable as POWER.
NOTE: not all installations will use red for power and black
for ground; therefore, it is important to disconnect the
wire shown as POWER ( ) on the existing wall plate.
Once the power has been disconnected, mark the cables
for ANTENNA, CABLE, TV1, and TV2. With these cables
marked, unscrew each of these cables from the existing wall
plate, making sure that they do not fall back into the wall.
Finally, disconnect the GROUND ( ) from the existing wall
plate. Now, nothing should be connected to the wall plate.
Set the existing wall plate aside; it is no longer needed.
Proceed to
Installing the SensarPro
.
Included:
2 Spade Connectors
4 Mounting Screws
1 Signal Meter Spacer (connected to wall plate)
1 SensarPro Wall Plate
1 Instruction Sheet
Installing the SensarPro
On the back of the SensarPro wall plate, there are four cables.
Each cable is labeled on the cover above the cable as shown
below.
3
= Antenna
4
= Cable
5
= TV2
6
= TV1
Connect the cable coming from the antenna to the cable
coming from ANT IN ( ) on the SensarPro. Repeat this for
CABLE IN, TV1, and TV2.
If more than two televisions are needed, a splitter may be
connected to TV2 to add televisions.
Once the four cables have been attached, connect the 12 VDC
power from the existing wall plate to the SensarPro. The
POWER should be connected to the post marked “
+
” ( ) on
the SensarPro. The GROUND should be connected to the post
marked “
−
” ( ) on the SensarPro. Input voltage must be
between 9 and 16 volts DC with a maximum draw of 500 mA.
1
= Power
2
= Ground
With all of the cables connected, carefully feed the cables
back into the hole in the wall. Align the mounting holes on the
SensarPro so that they form a line perpendicular to the floor. If
the spacer was installed, align the holes in the SensarPro wall
plate with the holes in the spacer. See image to the left.
Pre-drill mounting holes if this is a new installation.
Insert two of the provided mounting screws, and secure the
SensarPro to the wall. Proceed to the
Operation
section.
New Installation
Begin by selecting a location
for the Winegard SensarPro.
Keep in mind the following
about the SensarPro:
•
must be accessible
•
must be connected to the
antenna, television(s), and
12V DC power
•
will extend one inch into
the mounting surface
Try to avoid installing the
SensarPro on an exterior wall.
Once a location has been
selected, cut a 3.30” tall by
1.87” wide section in the wall
for the back of the SensarPro
and the cables. See actual
size template at right. If
unable to cut out the tabs
using the provided template,proceed to
Installing the Spacer.
Otherwise, proceed to
Installing the SensarPro
.
Installing the Spacer
If not using an outlet box or if unable to cut out the tabs on the
above template, the spacer may be
needed. (The tabs in the above template
are not needed when using the spacer.)
To install
the spacer,
place the
spacer over
the hole cut
out for the
SensarPro.
Screw the spacer to the wall
with two mounting screws. See
image above. Then, continue
with
Installing the SensarPro
.
InstallatIon InstructIons
Warranty
WINEGARD MOBILE PRODUCTS LIMITED WARRANTY
(2 YEARS PARTS; 1 YEAR LABOR)
Winegard Company warrants this product against defects in materials or workmanship
for a period of two (2) years from the date of original purchase. During year one (1) of
such warranty, Winegard Company will also pay authorized labor costs to an authorized
Winegard dealer to repair or replace defective products. No warranty claim will be
honored unless at the time the claim is made, Customer presents proof of purchase to an
authorized Winegard deal
er such as SolidSignal.com. Custo
mer must provide proof of
purchase with a dated sales receipt for the Winegard product to verify the product is under
warranty. If the date of purchase cannot be verified, the warranty period shall be
considered to begin thirty (30) days after the date of manufacture.
If a defect in material or workmanship is discovered, Customer may take the product to
an authorized Winegard dealer for service. Customer must provide proof of purchase to
verify the product is under warranty. If the product is brought to an authorized Winegard
dealer for service prior to expiration of year one (1) of the warranty period and a defect in
material or workmanship is verified by Winegard Technical Services, Winegard Company
will cover the Winegard dealer’s labor charges for warranty service. The Winegard dealer
must contact Winegard Technical Services in advance for pre-approval of the service.
Approval of the service is at the sole discretion of Winegard Company.
Alternatively, Customer may ship the product prepaid to Winegard Technical Services
(located at 3111 Kirkwood Street, Burlington, Iowa 52601. Customer must return the
product along with a brief description of the problem and provide Winegard Technical
Services with Customer’s name, address, and phone number. Customer must also provide
proof of purchase to verify the product is under warranty. If the product is returned before
the expiration of the warranty period, Winegard Company will (at its option) either repair
or replace the product.
This Limited Warranty does not apply if the product has been damaged, deteriorates,
malfunctions or fails from: improper installation, misuse, abuse, neglect, accident,
tampering, modification of the product as originally manufactured by Winegard in any
manner whatsoever, removing or defacing any serial number, usage not in accordance
with product instructions or acts of nature such as damage caused by wind, lightning, ice
or corrosive environments such as salt spray and acid rain. This Limited Warranty also
does not apply if the product becomes unable to perform its’ intended function in any way
as a result of the television signal provider making any changes in technology or service.
RETURN AUTHORIZATION POLICY
A Return Material Authorization (RMA) is required prior to returning any product to
Winegard Company or Winegard Warranty Services under this warranty policy. Please call
Solid Signal at 877.312.4547 t
o obtain the RMA number. Please furnish the date of
purchase when requesting an RMA number. Enclose the product in a prepaid package and
write the RMA number in large, clear letters on the outside of the package. To avoid
confusion or misunderstanding, a shipment(s) without an RMA number(s) or an
unauthorized return(s) will be refused and returned to Customer freight collect.
WINEGARD COMPANY DOES NOT ASSUME ANY LIABILITIES FOR ANY OTHER
WARRANTIES, EXPRESS OR IMPLIED, MADE BY ANY OTHER PERSON.
ALL OTHER WARRANTIES WHETHER EXPRESS, IMPLIED OR STATUTORY
INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND
MERCHANTABILITY ARE LIMITED TO THE TWO YEAR PERIOD OF THIS WARRANTY.
In states that do not allow limitations on implied warranties, or the exclusion of
limitation of incidental or consequential damages, the above limitations or exclusions do
not apply.
Some states do not allow limitations on how long an implied warranty lasts, or the
exclusion of limitation of incidental or consequential damages, so the above limitations or
exclusions may not apply to you.
This warranty gives Customer specific legal rights. Customer may also have other rights
that may vary from state to state.
Technical Service:
877-312-4547
For questions, contact Solid Signal at 877.312.4547
or e-mail [email protected].
Printed in U.S.A. ©2011 Winegard Company 2452217 Rev2 10/11
Winegard and SensarPro are registered trademarks of Winegard Company.
www.antennaweb.org and www.tvfool.com are not affiliated with Winegard Company.
2452217
In many cases, the Winegard SensarPro signal meter will replace an existing RV antenna wall
plate power supply. For this reason, both replacement instructions and new installation
instructions are provided.
The signal meter spacer is needed for most installations. If using an outlet box, the spacer is
not needed.
For more information on how to hook up your SensarPro, visit www.winegard.com/sensarpro
SensarPro Operation Instructions are included on the back of this page.
3
4
5
1 2
1.87”
3.30”
.14”
.12”
.25”
.25”
tab
ANT IN
TV
2
TV
1
CABLE IN
3
4
5
1
2
1
2
Spacer
SensarPro
Wall Plate
3
4
5
6
1
1
2
3
1
2