Environmental specifications
27
Relative humidity
Specifications
Storage
5% to 95% RH with 33°C (91°F) maximum dew point.
Atmosphere must be non-condensing at all times.
Operating
10% to 80% relative humidity with 29°C (84.2°F) maximum
dew point.
Table 19. Maximum vibration specifications
The maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The
maximum vibration specification of a non-operational system is 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Maximum vibration
Specifications
Operating
0.26 G
rms
at 5 Hz to 350 Hz (all operation orientations).
Storage
1.88 G
rms
at 10 Hz to 500 Hz for 15 min (all six sides
tested).
Table 20. Maximum shock specifications
The maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and
negative x, y, and z axes of 40 G for up to 2.3 ms. The maximum shock specification of a non-operational system is six
consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71
G for up to 2 ms.
Maximum vibration
Specifications
Operating
Six consecutively executed shock pulses in the positive and
negative x, y, and z axes
of 40 G for up to 2.3 ms.
Storage
Six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the
system) of 71 G for up to 2 ms.
Table 21. Maximum altitude specifications
The maximum altitude specification for an operational system is 3048 m (10,000 ft). The maximum altitude specification for a
non-operational system is 12,000 m (39,370 ft).
Maximum altitude
Specifications
Operating
30482000
m (
10,0006560
ft)
Storage
12,000 m (39,370 ft)
Table 22. Operating temperature de-rating specifications
If the operating temerature of a system is up to 35 °C (95 °F), the maximum temperature is reduced by 1 °C/300 m (1 °F/547
ft) above 950 m (3,117 ft). If the operating temperature of a system ranges from 35 °C to 40 °C (95 °F to 104 °F), the maximum
temperature is reduced by 1 °C/175 m (1 °F/319 ft) above 950 m (3,117 ft). If the operating temperature of a system ranges from
40 °C to 45 °C (104 °F to 113 °F), the maximum temperature is reduced by 1 °C/125 m (1 °F/228 ft) above 950 m (3,117 ft).
Operating temperature de-rating
Specifications
Up to 35°C (95°F)
Maximum temperature is reduced by 1°C/300 m (1°F/547 ft)
above 950 m (3,117 ft).