N_ONE
SRV_VCM_HALL_SENSOR_IS_NOT_CALIBRATED_US
E_DEFAULT
902h
Servo
Exception when hall sensor is not calibrated
SRV_UNTHREAD_UNPICK_EXCEEDED_RETRIES 903h Servo
Unable to unpick cartridge pin
SRV_REEL_SCREEN_TEST_REJECTED_CART_INSER
TED
904h
Servo
Reel motor screen test rejected because cartridge is inserted
SRV_REEL_SCREEN_TEST_BOTH_MOTORS_FAILED 905h
Servo
Both
the drive motor and cart motor failed the screen test
SRV_REEL_SCREEN_TEST_DRIVE_MOTOR_FAILED 906h
Servo
Drive
motor failed the screen test, while cart motor passed
SRV_REEL_SCREEN_TEST_CART_MOTOR_FAILED 907h Servo Cart
motor failed the screen test, while drive motor passed
SRV_CMDPROC_MFR_DATA_NOT_AVAILABLE_CHE
CKSUM_BAD
908h Servo
SRV_THREAD_STALL_NEAR_PIN_GRABBER_MOVER 909h
Servo
Thread Stalled near Pin Grabber Mover
SRV_THREAD_STALL_NEAR_GUIDES 90Ah
Servo
Thread Stalled near First Guides
SRV_THREAD_STALL_NEAR_HEAD 90Bh
Servo
Thread Stalled near Head
SRV_THREAD_STALL_PAST_HEAD
90Ch
Servo
Thread Stalled between the Head and the Drive Hub
TAPE_MFR_DATA_MISMATCH 90Dh
Tape
Auto Load detect Mfr Data from Servo and CM not match
TAPE_RSV_90E 90Eh
Tape
TAPE_RSV_90F 90Fh
Tape
DSM_CMPR_SKIP_INIT_BUFLIST_SHOULD_BE_EMPT
Y
910h Data
set
manager
An unexpected situation occurred while initializing to skip to the
target locati
DSM_CMPR_SKIP_TARGET_NOT_IN_DS 911h
Data
set
manager
Data processor did not find target in specified dataset
DSM_CMPR_USER_ADDR_OUT_OF_RANGE 912h
Data
set
manager
Firmware error detected while either reading or locating
DSM_CMPR_WR_UNDRUN_BUFLIST_RANGE_ERROR 913h
Data
set
manager
The number of buffers in the data compression engine was
found to be incorrect d
DSM_CMPR_WR_INTERRUPT_NOT_RECOGNIZED 914h Data
set
manager
An invalid interrupt was detected during write.
DSM_CANT_SWITCH_TO_READ_NO_DS 915h
Data
set
manager
The drive thinks it is positioned within a dataset, but when it
comes time to st
DSM_CMPR_READ_NO_DS_TO_SUPPLY 916h
Data
set
manager
Attempt to supply a dataset to the decompressor fails, because
there is no valid
DSM_CMPR_RD_BUFFER_MISSING 917h
Data
set
manager
Part of a dataset appears to be missing.
DSM_CMPR_SKIP_ACCESS_PT_BUF_INDEX_OUT_OF
_RANGE
918h Data
set
manager
Firmware calculation of access point buffer location resulted in
a value which w
DSM_CMPR_SKIP_FAILED_TO_FIND_ACCESS_PT_B
UFFER
919h Data
set
manager
While attempting to locate within a dataset, the buffer (partial
dataset) which
DSM_CMPR_SKIP_COULDNT_FEED_INTRA_DS_UND
ERRUN
91Ah Data
set
manager
While locating to a target, a buffer (partial dataset) was found to
be missing.
SRV_DATA_BAND_ID_ERROR_DURING_HEAD_CALIB
RATION
91Bh
Servo
Insufficient PES samples for data band ID after head offset
calibration
SRV_UNTHREAD_STALL_NEAR_DRIVE_HUB 91Ch
Servo
Unthread Stalled near or in Drive Hub
SRV_UNTHREAD_STALL_PAST_HEAD 91Dh
Servo
Unthread
Stalled between the second guides and the Head
SRV_UNTHREAD_STALL_NEAR_HEAD 91Eh
Servo
Unthread
Stalled between the second guides and the Head
SRV_UNTHREAD_STALL_NEAR_GUIDES 91Fh
Servo
Unthread
Stalled between the Pin Grabber Mover and the first
guides
SRV_UNTHREAD_RETRY_PULLING_TAPE
920h
Servo
Unthread retry while pulling tape.
SRV_UNTHREAD_PULLING_TAPE_EXCEEDED_RETRI
ES
921h
Servo
Unthread exceeded retries while attempting to recover from an
error during Unthr
SRV_THREAD_UNABLE_TO_LOCK_HUB 922h
Servo
Unable to lock inner hub to flange hub.
SRV_THREAD_RETRY_HUB_LOCK
923h
Servo
Drive Inner Hub Lock retry.
SRV_THREAD_HUB_LOCK_EXCEEDED_RETRIES 924h Servo Unable to lock inner hub to flange hub.
SRV_UNPICK_NO_PIN
925h
Servo
No pin detected during Unpick
TAPE_CART_NOT_SUPPORT 926h
Tape
Cartridge
not
support, servo writer cartridge type (last 4 bytes)
are invalid
SRV_HEAD_BRUSH_NEEDS_CART_LOADED_TO_CL
EAN
927h
Servo
HEAD_BRUSH command recieved when cartridge not loaded.
SRV_HEAD_BRUSH_HOME_NOT_CLEANING
928h
Servo
BRUSH_HOME command recieved when not brushing
SRL_INVALID_EVENT_ID_RECEIVED 929h
General
Task is sending wrong event ID to display events