SRV_EXT_DAC_NOT_CALIBRATED 8D3h
Servo
External dac is not calibrated, use default value
SRV_HEAD_AZIMUTH_MAX_MEAN_EXCEEDED 8D4h
Servo
SRV_HEAD_AZIMUTH_MAX_STDEV_EXCEEDED 8D5h Servo
SRV_HEAD_AZIMUTH_MAX_FWD_REV_DELTA_MEA
N_EXCEEDED
8D6h Servo
SRV_THR_TRAY_LOAD_ALREADY_AT_TRAY_IN 8D7h Servo Cart Tray already loaded when told to load
SRV_THR_CART_LOAD_MISSING_TRAY_IN 8D8h
Servo
Cart Loaded and never saw the TRAY IN sensor
SRV_THR_TRAY_UNLOAD_ALREADY_AT_TRAY_OUT 8D9h
Servo
Tray Unload detects it is already at TRAY OUT sensor
SRV_THR_CART_TRAY_LOAD_STALL 8DAh
Servo
Cart stalled during Load
SRV_THR_CART_TRAY_UNLOAD_STALL 8DBh
Servo
Cart Tray stalled during Unload
THR_PIN_GRABBER_HALL_NO_PICK_PEAK_RECOV
ERED
8DCh
General
Pin Grabber initialization failed and recovered.
SRV_MTR_LOG_FULL
8DDh
Servo
Reel task is trying to send more commands to ISR
SRV_MTR_UNEXPECTED_MESSAGE_RESPONSE 8DEh Servo
Motor task recieved unexpected response
SRV_MTR_ABORT
8DFh
Servo
Use for internal abort
SRV_MTR_TASK_BUSY
8E0h
Servo
Motor task is busy
SRV_MTR_ACTIVE_FUNCTION_IS_NULL 8E1h
Servo
Motor task try to execute null function
SRV_THR_CART_RECHUCK_NEVER_GOT_OFF_TRA
Y_IN
8E2h
Servo
Rechuck stuck at Tray In position
TAPE_READ_ONLY_FORMAT 8E3h
Tape
report
this
error status when write on read-only format tape.
SRV_REJ_THREADED
8E4h
Servo
Reject command because drive is threaded
SRV_MOTOR_BOT_OVERRUN 8E5h
Servo
MTR_INVALID_ALERT_RECEIVED 8E6h
General
MTR_INVALID_ERROR_ALERT_RECEIVED 8E7h
General
SRV_MTR_THIS_MOTOR_IS_NOT_ROTATING 8E8h
Servo
Can't stop this motor b/c it is not rotating
SRV_MTR_UNEXPECTED_MESSAGE_IN_IDLE_STATE 8E9h
Servo
This command is not expected in this state
SRV_MTR_UNEXPECTED_MESSAGE_IN_ROTATE_ST
ATE
8EAh
Servo
This command is not expected in this state
SRV_MTR_UNEXPECTED_MESSAGE_IN_POS_MOVE_
STATE
8EBh
Servo
This command is not expected in this state
SRV_MTR_UNEXPECTED_MESSAGE_IN_HOLD_TENS
ION_STATE
8ECh
Servo
This command is not expected in this state
SRV_MTR_UNEXPECTED_MESSAGE_IN_RAMPING_S
TATE
8EDh
Servo
This command is not expected in this state
SRV_MTR_UNEXPECTED_MESSAGE_IN_STEADY_SP
EED_STATE
8EEh
Servo
This command is not expected in this state
SRV_MTR_MAXIMUM_STATE_EXCEEDED 8EFh
Servo
This command is not expected in this state
SRV_UNTHREAD_UNABLE_TO_LOCK_DRIVE_FLANG
E
8F0h
Servo
Unable to Lock Drive Hub Outer Flange prior to unthreading
SRV_THR_FLANGE_NOT_LOCKED 8F1h
Servo
Flange not locked after Flange Lock
SRV_THR_FLANGE_STILL_LOCKED 8F2h
Servo
Flange still locked after after Flange Unlock
SRV_THREAD_FLANGE_NOT_LOCKED
8F3h
Servo
Flange not locked at start of Thread process
SRV_THR_AUTOLOAD_MECH_UNSAFE 8F5h
Servo
Autoload mechanics is unsafe
TAPE_SRV_SPEED_NOT_IN_RANGE 8F6h
Tape
Report Servo speed not suitable for writing or reading.
DSM_CMPR_RD_CHECK_RECSIZE_BUG_NO_DS_TO_
ADD
8F7h Data
set
manager
DSM detected missing DS while performing hardware
workaround
SRV_EVENT_UNTHREAD_PIN_GRABBER_STUCK_IN_
HUB_EXCEEDED_RETRIES
8F8h
Servo
Pin Grabber is stuck in the Drive Hub
SRV_UNTHREAD_PIN_GRABBER_STUCK_IN_HUB 8F9h Servo
Pin Grabber stuck in Drive Hub
SRV_REEL_PEOT_CAN_NOT_RAMP_IN_FORWARD
8FAh
Servo
Can't ramp forward peot point
SRV_REEL_PBOT_CAN_NOT_RAMP_IN_REVERSE 8FBh Servo
Can't ramp reverse past BOT point
SRV_VCM_BIAS_IS_NOT_CALIBRATED_USE_DEFAU
LT
8FCh Servo
SRV_PROGRAMMING_TZA_REG_BUSY 8FDh
Servo
SRV_FAILURE_DURING_TRK_WAITING_FOR_ONTRA
CK_DURING_BACKWARDS
8FEh
Servo
Servo Failure during tracking state waiting for ontrack in using
not default hea
DSM_CMPR_RD_CHECK_RECSIZE_BUG_ADDR_RAN
GE
8FFh Data
set
manager
Address range error during h/w workaround
SRV_SIGMA_CALC_OVERFLOW 900h
Servo
When
gathering data for sigma calculation overflow
SRV_SIGMA_CALC_COUNT_IS_NOT_GREATER_THA
901h
Servo
In sigma calulation counts has to be higher then 1