A – Command Line Interface
Show Command
A-46
59048-01 A
ns [option]
Displays name server information for the specified [option]. If you omit [option],
name server information for the local domain ID is displayed. [option] can have the
following values:
all
Displays name server information for all switches and ports.
[domain_id]
Displays name server information for the switch given by [domain_id].
[domain_id] is a switch domain ID.
[port_id]
Displays name server information for the port given by [port_id]. [port_id] is a
port Fibre Channel address.
pagebreak
Displays the current pagebreak setting. The pagebreak setting limits the display of
information to 20 lines (On) or allows the continuous display of information without
a break (Off).
panel
Displays the hardware configuration and port mapping for a SANbox2-64 switch.
The representation of the faceplate indicates power supply modules (PS), I/O
blades (IO), and CPU module (CPU).
perf [option]
Displays performance information for all ports. Refer to the
”Show Perf Command”
on page A-62
.
port [port_number]
Displays operational information for the port given by [port_number]. Ports are
numbered beginning with 0. If the port number is omitted, information is displayed
for all ports.
Table A-13
describes the port parameters.
Table A-13. Show Port Parameters
Entry
Description
AIinit
Incremented each time the port begins AL
initialization.
AIinitError
Number of times the port entered
initialization and the initialization failed.
ClassXFramesIn
Number of class x frames received by this
port.
ClassXFramesOut
Number of class x frames sent by this port.
ClassXWordsIn
Number of class x words received by this
port.
Содержание SANbox2 SANbox2-64
Страница 1: ...S i m p l i f y 59048 01 A Page i SANbox2 64 Switch Management User s Guide...
Страница 36: ...2 Using SANbox Manager Using the Faceplate Display 2 24 59048 01 A Notes...
Страница 62: ...3 Managing Fabrics Zoning a Fabric 3 26 59048 01 A Notes...
Страница 84: ...4 Managing Switches Restoring the Factory Default Configuration 4 22 59048 01 A Notes...
Страница 104: ...6 Managing Ports Testing Ports 6 16 59048 01 A Notes...
Страница 188: ...A Command Line Interface Zoning Command A 84 59048 01 A Notes...
Страница 214: ...C Messages Trap Configuration Dialog C 22 59048 01 A Notes...
Страница 218: ...D Glossary D 4 59048 01 A Notes...