Operating
screens
96
Operating manual HR9
– QS21XXXX
Pallet stopper
Setting
Description
Present
Yes = Present and use for pallet outfeeding
Blocked
Maximum time that it may take before the cylinder reaches the desired
position.
Photocell
Setting
Description
Delay on/off
This sets the sensor delay.
As soon as the sensor gives a signal, this can be influenced by an ON
delay and OFF delay.
In that case, the sensor must be covered longer before the machine
actually receives the signal (ON delay); it is also possible to keep the
signal high while the sensor is already uncovered (OFF delay).
Second pallet detection
Yes = The second photocell must also be covered before the pallet is
reported.
Pallet centring
Setting
Description
Present
Yes = Present and use empty pallet centring
Centring duration
Duration of centring empty pallet before centring returns to basic
position
Blocked
Maximum time that it may take before the cylinder reaches the desired
position.