Notifications
132
Operating manual HR9
– QS21XXXX
No.
Action
Description
Cause
Solution
391
HOLD
Twistrunner; Unknown object
Beams of lightgrid blocked
while no data is available
Check conditions of product
data and status lightgrid
Adjust to the correct situation
392
HOLD
Twistrunner; To many objects
To many objects in lightgrid
Maximum of 2 objects allowed
on conveyor
Check conditions of product
data and status lightgrid
Adjust to the correct situation
393
HOLD
Twistrunner; Rotation not
succesfull, time limit exceeded of
wrong orientation
Rotation of product takes
more time
then normal
Lower speed of rotation
Check if object is blocked or
slipping on conveyor.
Remove object from conveyor
394
HOLD
Twistrunner; Inverter left side
blocked
The inverter drive is
malfunctioning. The inverter
drive always provides a fault
code in the event of a fault.
From this error code a short
description of the error is
given.
Example:
Fault code 8: Speed
monitoring
Check the current fault code in
the diagnostics menu.
You can find extensive
information and help regarding
this code
in the manufacturer’s
documentation
395
REFERENCE Twistrunner; Inverter left side not
referenced
Motor & inverter drive not
referenced.
Motor has lost position or has
been shown to be unreliable
due to
inverter drive faults
The referencing (homing)
cycle is started automatically
during machine reset
If the machine needs
confirmation regarding
position
of parts, a pop-up window will
appear
396
HOLD
Twistrunner; Inverter left side
offline
Communication lost between
PLC and inverter / drive.
No connection established.
Warn technicians and OEM
Use diagnostics and
documentation to detect the
problem and how to solve it
Make sure the inverter & drive
have power available
397
REFERENCE Twistrunner; Inverter right side
blocked
See Alarm 394
See Alarm 394
398
HOLD
Twistrunner; Inverter right side
not referenced
See Alarm 395
See Alarm 395
399
HOLD
Twistrunner; Inverter right side
offline
See Alarm 396
See Alarm 396
400
HOLD
Twistrunner; Product outside
conveyor while turning
The first or the last beam of
the lightgrid
gets blocked while turning.
Remove product from
conveyor
Recover machine
Adjust turning settings of
actual program
401
HOLD
Twistrunner; Product incorrect
dimensions
Product dimension of product
not
within settings of actual
program
Remove product from
conveyor
Recover machine
Check product dimensions
and orientation