Notifications
128
Operating manual HR9
– QS21XXXX
Alarm list
No.
Action
Description
Cause
Solution
1
ABORT
Safety: Emergency stop circuit
interrupted
Emergency stop circuit
interrupted
Unit aborted.
Please check why emergency
stop has been pushed
Pull out the emergency stop
and reset safety circuit
with the unit reset button
NEVER RESET AN
EMERGENCY BUTTON WITH
STILL
PERSONS NEAR OR WITHIN
THE MACHINE
2
ABORT
Safety: Emergency stop control
panel (HMI) pushed
Emergency stop pushed on
HMI.
Unit aborted.
Please check why emergency
stop has been pushed
Pull out the emergency stop
and reset safety circuit
with the unit reset button
NEVER RESET AN
EMERGENCY BUTTON
WITH STILL
PERSONS NEAR OR WITHIN
THE MACHINE
15
ABORT
Safety: Door switch 1 circuit
interrupted of access to product
formation
Door opened giving access to
product formation
Close the door
Reset safety circuit with reset
button on control panel
near the door
NEVER CLOSE A DOOR
WITH STILL PERSONS
NEAR OR WITHIN THE
MACHINE AREA
29
ABORT
Safety: Safety zone of pallet
handling interrupted
Safety zone pallet handling
(other installation) interrupted
Check why safety circuit is
interrupted.
Please advise operation
manual of pallet handling
39
ABORT
Safety: Safe communication with
downstream (pallet handling)
offline
PLC detects a problem with
communication with the
profinet PLC partner.
PLC can't reach partner or
communication is delayed
outside time limits.
For safety reasons machine is
aborted
Check physical connection
between PLC
Validate that both PLC are in
RUN mode
Reset / Clear both installation
to restart communication
If alarm is gone,
communication is online
40
ABORT
Safety valve feedback error zone
palletizer
Safety valve feedback
sensors does not switch
correctly
or within maximum time limits
Reset the fault, make sure air
supply is present
and valve sensors are
working/adjusted
correctly
45
ABORT
Safety relay feedback error zone
palletizer
Safety relay feedback contact
does not switch correctly
or within maximum timelimits
Reset the fault, make sure
relay functionality is correct
and feedback contact
functionality is correct