Please check the LCD screen on top cover of PCS. Follow the instruction below for battery communication.
7.3.5 Battery Installation Process with HMI
Step 1 )
Touch Battery Icon 10 times.
Step 2 )
Select. [Initial ID]
Step 3 )
Click Next Button.
Step 4 )
• All Battery Pack Communication Cables are
Connected. Open circuit breakers.
Entering Initial Installation Information
I
56
1
2
3
Step 5 )
Click Next Button.
Step 6 )
Check Initialization Success Message.
• If there is Failure Message, Click Stop Button
and Check Communication Line.
Go to Step 2. [Initial ID]
5
Step 7 )
Click Finish Button when Initialization is successful.