11
I
Safety
[ Table 2-4 : Basic Specifications (Australia & New Zealand) ]
2.3.4 Basic Specifications (Australia & New Zealand)
Grid Connection Data (AC)
Battery Data (DC)
PV Generator Data (DC)
Max. input total power
Max. input power per string
Max. input voltage
Min. input voltage / Initial input voltage
MPPT voltage range
Max. input current per string
Number of independent MPPT trackers
Rated power (at 230V, 50Hz)
Max. output apparent AC power
Max. current
Nominal AC voltage / range
Rated power frequency / range
6.6 kWp
3.3 kWp
550 V
125 V / 150 V per string
125 V - 500 V
15 A per string
2
47 - 52 HZ
45 - 52 HZ
5.0 kW
5.0 kVA
25 A
230 V / 181 V
AC
- 259 V
AC
Australia
New Zealand
Battery nominal capacity
DOD (Depth of Discharge) Range
Battery voltage range / nominal voltage
Max. discharge current
Max. charge current
Max. charge power (Rated power)
Short circuit current
Battery nominal capacity
DOD (Depth of Discharge) Range
Battery voltage range / nominal voltage
Max. discharge current
Max. charge current
Max. charge power (Rated power)
Short circuit current
Max. discharge power
Battery technology
DC/DC converter technology
Over voltage Category
1 Battery Pack
2 or more Battery Pack
4.0 kWh
9.8 A
2.0 kW (0.8 kW)
6.3 kWh
15.6 A
15.6 A
4.0 kWh x Pack
17 A
3.0 kW (0.8 kW x Pack)
6.3 kWh x Pack
17 A
17 A
176.4 Vdc - 225.12 Vdc / 203.84 Vdc
173.6 Vdc - 228.2 Vdc / 202.7 Vdc
90 %
90 %
3.0 kW (1.25 kW x Pack)
1070.5 A (0.4 ms)
3.0 kW
Rechargeable Li-Ion
Non-Isolated
II
17 A
771.25 A (701
μ
s)
Q.SAVE
G2
4kWh
Q.SAVE
G2
6.3kWh
Содержание Q.VOLT-G2 HYB-4.6kW.1.1
Страница 117: ......