Problem Confirmation
9. Problem Confirmation
Checking event codes is available on the website (www.q-cells.com).
If the Internet is not available, the event codes cannot be checked.
9.1 General Events
The general events contain warnings and protection.
The warning level events does not stop the generating process. A displayed warning message automatically
disappears as soon as the issue is resolved.
When protection level events occur, the product stop the generating process. The process may automatically
resume as long as the issue is resolved.
9.1.1 INVERTER General Events (Protection)
Type : PROTECTION
The product stops the generating process
because a significant protection event has
occurred. Wait until the event message
disappears. After the event message is
removed, it automatically returns to normal.
If it is not removed until the time limit is
reached, it is converted to a significant event.
BDC Current Trip
Zone Master Protection
BDC I TZM P
D01P
WEB Display
HMI Display
Description
Measures
The product stops the generating process
because a significant protection event has
occurred. Wait until the event message
disappears. After the event message is
removed, it automatically returns to normal.
If it is not removed until the time limit is
reached, it is converted to a significant event.
BDC Current Trip
Zone Slave Protection
BDC I TZS P
D02P
The product stops the generating process
because a significant protection event has
occurred. Wait until the event message
disappears. After the event message is
removed, it automatically returns to normal.
If it is not removed until the time limit is
reached, it is converted to a significant event.
BDC1 Charge RMS
Over Current Protection
BDC1 COC P
D03P
The product stops the generating process
because a significant protection event has
occurred. Wait until the event message
disappears. After the event message is
removed, it automatically returns to normal.
If it is not removed until the time limit is
reached, it is converted to a significant event.
BDC1 Charge Over
Current Peak Protection
BDC1 COCP P
D04P