![Pyramid Technical Consultants F3200E Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/pyramid-technical-consultants/f3200e/f3200e_user-manual_1632602015.webp)
PSI System Controls and Diagnostics
F3200E User Manual
F3200E_UM_180726 Page 15 of 107
Actuator I/O port with sw24 VDC, sw5 VDC output suitable for driving a
pneumatic actuator solenoid plus two opto-isolated digital inputs suitable for reading limit
switches.
General purpose I/O port with three precision analog outputs, four precision differential analog
inputs, four TTL digital outputs, four TTL digital inputs.
Analog output 1 can be set as a real time monitor of sum of any selected channels.
Two fiber-optic digital outputs for process control
Auxiliary HV output option up to + or – 2000 VDC.
HV input for loopback verification of HV bias on external electrodes.