PSI System Controls and Diagnostics
F3200E User Manual
F3200E_UM_180726 Page 102 of 107
27
Maintenance
The F3200E does not require routine maintenance, except to clear any dust accumulation in the
fan filter.
There is risk of contamination which may degrade performance if the case is opened. There are
no user-serviceable parts inside.
CAUTION. High voltages may be present inside the case. Do not open the case when power is
applied.
If there is buildup of dust in the filter, you should clear this by vacuum cleaning in situ, or by
removing the filter element and cleaning it separately with an air jet. Note that detaching the
filter element also detaches the fan from the case.
Figure 79. Fan filter removal
The F3200E is fitted with a 1.1 amp automatically resetting positive temperature coefficient
(PTC) fuse in the 24 VDC input, and various similar fuses of lower ratings for 24 V outputs. No
user intervention is required if the fuses operate due to overcurrent. The fuse will reset when the
overcurrent condition ends.