ENGLISH
Protectoplus Lager- und Umwelttechnik GmbH
, Tel. +49 4331/4516-0, Fax +49 4331/4516-11
Internet:
www.protecto.de
, E-mail:
- 62 -
•
Repairs: Repair work may only be carried out by authorised persons.
•
Maintenance: The device must be checked by an authorised person as and
when necessary (once a year as a minimum) in accordance with TRbF 20
Section 15.4. The filters must be replaced or cleaned at the same time.
Replacement filters can be ordered from the supplier. We recommend
stocking a set of replacement filters to avoid interrupting operation. The
device records the operating time internally and outputs an audible signal
(one 3-second beep every hour after 365 days) to indicate that maintenance
is due.
12.6.4.
Troubleshooting
Fault
Cause
Remedy
Device not working
No power
Fuse defective
Device defective
Check the mains voltage
Replace the fuse of the mains
connector
Send in the device
Red flow lamp ON
Dust filter clogged
Volume flow interrupted
Replace the coarse filter
Replace the fine filter
Remove the obstruction from the
exhaust vent
Red saturation lamp
ON, audible signal,
air flow interrupted
Activated carbon filter
saturated
Concentration of
hazardous substances too
high
Other hazardous
substances contained in
exhaust air
Replace the filter
Check the contents of the cabinet and
remove any leaked substances
Start up the device again (authorised
persons only)
Contact the supplier