5.24
Unscrew valve.
Clean valve, purge with compressed air.
Change copper seal.
Screw in valve, fill air tank, and check tank tightness.
Cleaning valve:
•
every 12 months (before winter period).
5.3.6 CLEANING AND MAINTAINING PNEUMATIC CONDUIT CONNECTIONS
AND PNEUMATIC SOCKETS
DANGER
Unreliable and dirty trailer connections may cause unreliability and faulty functioning of
braking system.
Inspecting trailer connections:
•
connection should be inspected every time before connecting trailer to
tractor or second trailer.
Damaged connection body or socket for connecting the second trailer should be replaced. In
event of damage to cover or seal, change these elements for new reliable elements. Contact
of pneumatic connector seals with oils, grease, petrol etc. may cause damage and accelerate
ageing process.
If the trailer is unhitched from the tractor, connections should be protected by covers or
placed in their designated sockets. Before the winter period it is recommended to preserve
the seal with special preparations (e.g. silicon grease for rubber elements).
Each time before connection of the machine inspect technical condition and cleanness of
contacts and sockets in tractor. If necessary clean or repair tractor sockets.
Содержание T286
Страница 2: ......
Страница 6: ......
Страница 11: ...SECTION 1 BASIC INFORMATION ...
Страница 25: ...SECTION 2 SAFETY ADVICE ...
Страница 41: ...SECTION 3 DESIGN AND OPERATION ...
Страница 75: ...SECTION 4 CORRECT USE ...
Страница 117: ...SECTION 5 MAINTENANCE ...
Страница 155: ...SECTION 5 Pronar T286 5 39 FIGURE 5 14 Trailer s lubrication points part 1 ...
Страница 156: ...Pronar T286 SECTION 5 5 40 FIGURE 5 15 Trailer s lubrication points part 2 ...
Страница 165: ...NOTES ...
Страница 166: ... ...