3302C Series Mainframe Operation Manual 3-5
The EDIT MODE flow chart is described below:
3.4.1.1
There are nine Auto Sequence (n1-n9) can be edit within 3302C
3.4.1.2 Each Auto Sequence has up to 16 Test step, where each step is
any one memory of 150 sets Store memory which is 30 memory
Bank with 5 memory state.
3.4.1.3 Each test step has t1 (test time) and t2 (delay time), the unit is
100mS, the range is 0.1S - 9.9S in 100mS resolution. 3302C
mainframe will check each module GO/NG at the end of t1 (test
time), the next step will be started after duration t2 (delay time).
3.4.1.4 The test step sequence can be up to 16 step, and can be
terminated by press EXIT key if less than 16 step is required.
S3+S4
Show n1-n9
Store Mode
1.Press S3+S4 key
2.Show AUTO SEQ. No.1-No.9,
Press Up/Down key to set n1-n9
Press Store
3.Press Store key to Store Mode
Set Bank
Press Up/Down key to set Bank No.
Set State
Set State No.1~5
Show t1
Set T1
Press Up/Down key to set T1,
t1 = 01-99, Unit = 100mS
Exit
Press Exit key
Show SP= 0
Set T2
Step = F?
Yes
Yes
End?
Sp=Sp+1
Initial=n1~n9
Sp = 0 ~ F(16 step)
Show t2
Press Store key to next item
When press Store key, LED show t1
Press Store key to next item
When press Store key, LED show t2
Press Up/Down key to set T2,
t1 = 00-99, Unit = 100mS
Press Store key to next item
Is last step (16 step)?
Press Exit key
Fig 3-4 STORE (EDIT) MODE OPERATIONO FLOW-CHART