18.
witch in the on position. (Treadmill Only)
19.
If none of the keys on the display are functioning, check the stop switch cable connection to the upper PCA
e
display keys will operate. This feature insures that the treadmill has a functioning stop switch when it is in
20.
If a particular key is not functioning, perform the keyboard test in
Procedure 6.2.
If the test verifies that
the key is not functioning, replace the display face.
21.
If the display face has been replaced and the same key or control is still not functioning, replace the upper
PCA.
22.
If you have performed steps 18 - 22 and the same key is still not functioning, contact Precor customer
support for assistance.
23.
Remove the keypad cable from the upper PCA.
See Diagram 6.5.8.
24.
pedaling.
25.
If the
STUCK KEY
message is no longer displayed, replace the display face. If the
STUCK KEY
message is
still being displayed continue with step 26.
26.
27.
Remove the Machine Control cable from the upper PCA.
28.
pedaling.
29.
If the
STUCK KEY
message is no longer displayed, replace the machine the display face.
30.
If the
STUCK KEY
is still being displayed with the keyboard cable disconnected, replace the upper PCA.
31.
If you have performed steps 23 - 30 and the
STUCK KEY
message is still being displayed, contact Precor
customer support for assistance.