24.
Access the diagnostic program (Procedure 6.1). Advance to the heart rate display portion of the diagnostic
program. Verify that neither a chest strap signal or a hand held signal is being accepted with either a heart
rate test transmitter or a chest strap transmitter.
25.
Check the plug/connector connections on both the hand held heart rate (JK7) and wireless heart rate
(JK8) at the upper PCA.
26.
If neither a chest strap signal or a hand held signal is being accepted, measure between the replace the
upper PCA.