EFX 885, 835, 825
Service Manual 20039-166
Page 117
©2011 Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Procedure 6.7 P20 Replacing Heart Rate PCA
1.
Set the treadmill circuit breaker in the off
(Treadmill only).
2.
Remove the console access panel per procedure 6.5.
3.
are static sensitive. They can be damaged if proper static prevention equipment is
not used. Attach an anti-static wrist strap to your arm, and then connect the ground lead of the wrist strap
to the frame ground.
4.
Disconnect the HR cable connector from the upper PCA.
5.
Remove the HR PCA access panel on the back of the console.
See Diagram 6.7.1
6.
The HR PCA snaps into its mounting. Press its tabs downward and remove the HR PCA from its mounting.
7.
Pull the HR PCA cable out of the console.
8.
Route and the new HR cable through the console and reconnect it onto the upper PCA.
See Diagram 6.7.2
.
9.
Snap the HR PCA into its mounting.
10.
Replace the HR PCA access panel removed in step 5.
11.
Replace the console access panel removed in step 2.
12.
Check operation per Section 7.