Troubleshooting 3.29 - P80 Touch Screen Responds Incorrectly to Touch
Description
Touch screen reads touches, but it is not registering them where the user is touching the screen.
Possible Causes
1.
The touch screen was improperly calibrated or has fallen out of calibration.
Possible Remedies
1.
Use Single Secret Handshake to enter screen calibration.
See Single Secret Handshake Procedure below.
See Procedure 3.6, Systems Test.
Ensure the person
recalibrating is standing on the machine and is not holding on to the console or any other part of the machine
while doing so.
Single Secret Handshake Procedure
Press the Pause key and continue holding it down while you press in sequential order an U configuration on the
Volume and Channel key pad (
Channel Up,
Channel Down,
Volume Down,
Volume Up).
See Diagram
3.27.1.
Release the Pause key when done pressing the arrows. Note: The keypad U configuration sequence
should be not faster than 1 second between each key stroke. Any speed faster than 1 second may result in an
unsuccessful access to the sign-in screen.
Diagram 3.27.1
1
3
4
2
Volume &
Channel Key Pad
Pause Button