17.
Connect the Metrics cable to the Metric PCA.
18.
Replace the P30 Rear Cover removed step 11 and secure the cover with the screws 6 screws. Torque to 10 inch
pounds.
Note:
Do not use an electric screw driver or over tighten the screws. Over tightening may damage
the console. This type of damage is not covered under warranty.
19.
Replace the P30 Option Cap back cover removed step 12 and secure the cover with the screws 2 screws. Torque
to 10 inch pounds.
Note:
Do not use an electric screw driver or over tighten the screws. Over tightening may damage
the console. This type of damage is not covered under warranty.
20.
Place the P30 console on the maintenance access hook.
21.
Reconnect the Data cable, Auto Stop cable (Treadmill only), Stop Key cable (Treadmill only), Heart Rate ground
wire and the CSAFE cable (if in use) from the Upper PCA.
See Diagram 5.6.5.
22.
Reconnect the Heart Rate Cable to the Heart Rate PCA.
23.
Replace the Heart Rate PCA.
See Procedure 5.7, Removing Heart Rate PCA
24.
Replace the access cover with the hardware removed in step 6.
25.
Tilt the console back against the mounting plated. While tilting the console back feed the excess cable into
weldment tube making sure that the cables will not become pinched.
26.
Fasten the console to the dash mounting plate with the four screws removed in step 4.
See Diagram 5.6.2.
27.
Fasten the dash transition cover using the two screws removed in step 3.
See Diagram 5.6.1
Check treadmill operation per Section Seven.