EFX 885, 835, 825
Service Manual 20039-166
Page 79
©2011 Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Procedure 5.7 P30 Replacing Heart Rate PCA
1.
Set the treadmill
(Treadmill only).
2.
not used. Attach an anti-static wrist strap to your arm, and then connect the ground lead of the wrist strap
to frame ground.
3.
Remove the HR PCA access panel on the back of the console.
See Diagram 5.7.1
4.
The HR PCA snaps into its mounting. Press its tabs downward and remove the HR PCA from its mounting.
5.
Disconnect the HR cable and handlebar cable from the HR PCA.
See Diagram 5.7.2.
6.
Connect the HHHR Grip cable assembly to the upper connector on the HR PCA and the HR PCA Power
cable to the lower connector on the replacement HR PCA.
See Diagram 5.7.2
.
7.
Orient the replacement HR PCA so that the side with the protective foam pad is facing out and snap the HR
PCA into its mounting.
8.
Replace the HR PCA access panel removed in step 3.
9.
Check operation per Section 7
cedure 6
Diagram 5.7.1
HR PCA Access Panel
Содержание EFX 825
Страница 15: ......