Procedure 10.8 Replacing the Generator Pulley Belt
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in Section One, Things You
Should Know.
1.
Remove the left and right side rear covers per Procedure 10.1.
2.
Remove the stairarm assemblies as described in Procedure 10.13
3.
Remove the crankarm assemblies as described in Procedure 10.5.
4.
Remove the input pulley assembly per Procedure 10.9
5.
Remove the left and right tension bolts, locking tabs and brackets from the step up pulley assembly.
6.
Remove the three generator mounting screws shown in Diagram 8.2.1.
7.
Remove the two bearing clamp screws shown in Diagram 10.17.2. Remove the bearing clamp.
8.
Lift the generator and remove its drive belt.
9.
Slide the step up pulley assembly with both the generator and input belts out of the drive unit.
10.
osition on the step up
pulley assembly.
11.
Set the step up pulley assembly with the generator and input belt at its mounting position in the drive unit.
Replace the tensioning bolts, locking tabs and brackets removed in step 6. Thread, but do not tighten, the
left and right tension bolts into the step up pulley shaft.
12.
13.
Replace and tighten the three generator mounting screws removed in step 6. Set the bearing clamp in its
mounting position, replace and tighten the two bearing clamp mounting screws removed in step 7.
14.
Mount the input assembly per Procedure 10.9.
15.
Replace the crankarm assemblies per Procedure 10.5.
16.
Replace the stairarm assemblies per Procedure 10.13.
17.
Tension both belts per Procedure 8.2. Note the differences between tensioning a new belt and an existing
(used) belt.
18.
Check the operation of the EFX as described in Section Seven.