44
Operating Manual
DE
EN
FR
IT
ES
PT
NL
SV
FI
DA
NO
EL
CZ
HU
PL
HR
SR
SK
SL
ET
LT
LV
RO
BG
MK
The
CHARGE
STATUS
button lights up red.
The
DOMESTIC
CONNECTION
indicator light
lights up red.
The
VEHICLE
indicator light lights up red.
The protective conductor is
interrupted/not present
e
Disconnect and re-connect the power plug.
e
Non-earthed
mains supply systems (e.g. IT networks) only: If neces-
sary, charge the vehicle with protective conductor monitoring
deactivated.
f
Refer to chapter “Deactivating ground monitoring” on page 39.
e
Only
earthed
mains supply systems: Have the control unit checked
by a qualified specialist workshop/Porsche partner. Have the mains
supply/domestic connection checked by a qualified electrician.
The
CHARGE
STATUS
button lights up red.
The
DOMESTIC
CONNECTION
indicator light
flashes red.
Overvoltage
e
Disconnect and re-connect the power plug.
e
If this does not remedy the fault, have the domestic installation
checked by a qualified electrician.
The
CHARGE
STATUS
button lights up red.
The
VEHICLE
indicator light lights up red.
Overload
e
Disconnect and re-connect the power plug.
e
If this does not remedy the fault, have the domestic installation
checked by a qualified electrician.
The
CHARGE
STATUS
button lights up red.
The
CHARGER
indicator light lights up red.
Relay fault
e
Disconnect and re-connect the power plug.
e
If this does not remedy the fault, have the domestic installation
checked by a qualified electrician.
The
CHARGE
STATUS
button lights up red.
The
CHARGER
indicator light flashes red.
Self-test failed
e
Disconnect and re-connect the power plug.
e
If this does not remedy the fault, have the domestic installation
checked by a qualified electrician.
The
CHARGE
STATUS
button pulses red.
The
CHARGER
indicator light lights up red.
Load cycle error
e
The charger is defective and must not be operated. Visit a qualified
specialist workshop/Porsche partner.
The
CHARGE
STATUS
button in accordance with
the charge status.
The
ENERGY
MANAGER
indicator light lights up
red.
The
50 %
indicator light lights up green.
PLC or energy manager connec-
tion error
e
During initial operation, restart the charger and repeat start-up.
Check the connection to the PLC network. Check the connection to
the energy manager.
The
CHARGE
STATUS
button lights up red.
The
DOMESTIC
CONNECTION
indicator light
lights up yellow.
Infrastructure plug overtemper-
ature
e
The device has switched off due to overtemperature. Wait until the
normal temperature is reached again. If necessary, protect the
charger from direct sunlight.
The
CHARGE
STATUS
button lights up red.
The
DOMESTIC
CONNECTION
indicator light
flashes yellow.
Undervoltage/invalid mains
frequency.
e
The charging process was interrupted. Wait. Do not take any action.
Indicator lights
Meaning
Remedy