Polycom Web
Office Release Notes Version 7.0.1
30
To configure the apserver.xml file and send it to the MCU:
1.
Copy the
apserver.xml
file to your local disk.
2.
Open the file in a text editor application.
3.
Edit the values of the following elements:
4.
Save the new values and close the file.
5.
Send the edited
apserver.xml
file to the MCU using the MGC Manager: In the
MGC
Manager
application, right-click the
MCU
icon, click
MCU Utils
and then click
Send
File
.
6.
Reset the MCU.
Table 2: apserver.xml File Configuration
Element
Description
IP
The IP address of the external application server. Enter the IP
address of the Web
Office server.
Port
The port number used by the MCU to access the external
application server. When working with the Web
Office server, use
port 5001 or 1205.
Login
The user name defined in the external database application for the
MCU. For the Web
Office application, the default user name is:
ACCORD
.
Password
The password associated with the user name defined for the MCU
in the external database application. For the Web
Office application,
the default password is:
ACCORD
.
Directory
The URL of the external database application. For the Web
Office
server, this is
McuIntergration
.