HOSE PACKAGE
Clean with water and a soap-solution.
AIR-COMPONENTS
Use compressed air to blow equipment clean.
SBT-RAIL AND SUSPENSIONS
Clean with water and a soap-solution
You observe that....
Why ?
What to do ?
The Grabber® does not connect
tightly to the tailpipe
The pressure in the Grabber® is not
high enough.
The pressure at the SBT-Presure re-
gulator should be increased (0,7-max
1,0 Bar)
The inflation time of the Grabber®
takes a long time
Leakage in the pressure air system
Seal the leakage.
You cannot operate the MFD opera-
ting valve good enough.
The MFD valve is not connected
correctly.
Un-twist the exhaust removal hose
either at the connection between the
hose and duct, or saddle which should
make operating the MFD valve pos-
sible again.
The Grabber® is dragging over the
floor or is is pushed back too far.
The Grabber® is hanging too low, the
balancer force is too strong.
Disconnect the saddle and reposition
it so that the hose is off the floor.
Or adjust the balancer force on the
balancer.
The Grabber® is transported out
of the Garage too far and the hose
swings back forcefully.
The disconnect point is too far for-
ward.
The release valve or (and) the end
stop should be moved further back
onto the rail.
The Grabber® opens when the vehic-
les drives into the station.
The release valve releases air when
the vehicle is moved into the station.
The MFD pressure valve can be stuck,
or the release valve on the trolley is
positioned too high.
The Grabber® does not close while
the manometer indicates there is
pressure.
The pressure air line in the hose is
twisted and / or blocked.
Disconnect the hose and check the
pressure air lines in the hose and un-
twist / unblock them.
The level of Service and Maintenance on the Plymovent
systems is relatively low. The Service and Maintenance
department of Plymovent consists of well trained personnel
who can offer you a Service and Maintenance contract which
ensures your system will function for many years to come.
Disposal
- Cardboard packaging
Recycle
- Aluminium profile
Recycle
- Hose
Rest waste
- Grabber® Nozzle
Rest waste
12. DISPOSAL
When dismantling the system please ensure to follow the
similar safety precautions as mentioned in this manual for
installation.
Dismantling must be done contrary to the installation
instructions.
Dismount loose parts before the rail is dismounted.
PUM_SBT_091102_EN
35/38
ATTENTION
Do not use solvents to clean the system.
11.
Cleaning and FAQ