INSTALLATION - TRIMMING PROCEDURE
PLAN VIEW
TRUCK-SIDE VIEW
1. SBT-Profile:
2. Release valve
3. Unregulated air for release valve (6 - 8 bar)
4. Regulated air for Grabber®
®
(coloured hose 0,7-1,0 bar):
5. Regulator with manometer
6. Compressed air feeder (6 - 8 bar)
7. MFD-valve
The compresed air (max. 8 bar) is connected to the
compressed air feeder (6).
Unregulated air (3) is connected via the 8mm air hose to
the release valve (2). This unregulated air is then connected
from the release valve through the rubber grommet on the
hose holder down through the exhaust hose and connected
to fitting S on the MFD valve.”
Regulated air (4) is connected from the regulator (5)
through the rubber inlet in the hose holder down through
the exhaust hose to the side of the MFD-valve (7).
Use the colours of the air hoses for orientation.
From the MFD-valve (7) an 8mm air hose connects down to
the Grabber
®
.
3
4
3
6
5
2
3
3
1
2
8 mm
6 mm
CAUTION
Please test if the pressure air hoses are connected
into the system in the correct way ( 0,7-1,0 bar)
before you pressurise the system. Also test the
pressure air system after the safety disconnect has
released.
P
A
S
R
Pneumatic version of the Safety Disconnect handle
In case of maintenance or adjustment of the Pneumatic valve
please note the following:
Upper fitting
P
1 bar in
Lower fitting
S
8 bar in
Grabber® connection A
Release
R
(leave open)
3
7
4
ATTENTION!
Please ensure that the compressed air delivered to
the Plymovent system is dry and clean. Failure to
supply this air may result in failure of the system.