1
4
3
2
8
6
7
5
PUM_SBT_091102_EN
23/38
Exit
Floor
BALANCER/SADDLE MOUNTING PROCEDURE
1.
SBT-profile
2.
Trolley with disconnect plate
3.
Balancer with safety chain and locking cable.
4.
Measurement, safety chain to floor minus 250mm
5.
Measurement, saddle to Grabber
®
nozzle
6.
Grabber
®
nozzle
7.
Saddle ring
8.
Grabber
®
nozzle 250mm height
over floor
a) The trolley (2) is slided in to the SBT-profile (1).
b) The balancer (3) is hung in the forward/lower suspension
hole with the wire towards the door, and the safety
chain facing towards the back of the parking area. Please
see balancer instructions for the correct settings of the
balancer.
c) The Balancer locking cable is connected between the
hose saddle and the trolley.
d) Measure the distance between the safety chain and the
floor and subtract 250mm (4).
e) This measurement is used to determine the
measurement (5) from the Grabber® opening to the
saddle ring (7).
f) The saddle is to be aligned according to: "Hose alignment
procedure" please see chapter Trimming Procedure of
this Product User Manual.
8.
INSTALLATION
WARNING
PRODUCT MAY CONTAIN SHARP EDGES
Use care when servicing unit. Failure to do so could
result in minor personal injury.