![Plymovent SBT-Pneumatic SBTP-6-100-100 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/plymovent/sbt-pneumatic-sbtp-6-100-100/sbt-pneumatic-sbtp-6-100-100_product-user-manual_1569244016.webp)
4
5
6
3
2
1
=
=
PUM_SBT_091102_EN
16/38
PLAN VIEW
HOSE CONNECTION DRIVE-THROUGH
LOCATION PROCEDURE
1.
SBT-track
2.
Hose connection
3.
Distance entrance gate-exit gate
4.
Entrance gate
5.
Exit gate
6.
Exhaust pipe
a) The hose connection (2) is positioned according to what
side of the vehicle the exhaust pipe (6) is positioned on.
b) The hose connection (2) is mounted on the SBT-track on
the opposite side of the vehicle.
c) At a drive-through station the hose connection (2) shall
be positioned on the SBT-track (1) at the half distance,
between entrance gate (4) and exit gate (5).
8.
INSTALLATION
WARNING
PRODUCT MAY CONTAIN SHARP EDGES
Use care when servicing unit. Failure to do so could
result in minor personal injury.
CAUTION
Before lifting the rail be sure that, the trolley is fixed
in its place, using both end stops. This to avoid injury
when trolley moves if the rail is uneven lifted.