2
1
PUM_SBT_091102_EN
30/38
9.
INSTALLATION - TRIMMING PROCEDURE
BALANCER SETTING PROCEDURE
1. Balancer
2. Balancer safety chain
The balancer is factory delivered at a pre-tension. In order to
make sure the balancer is functioning optimally please follow
the following procedure:
a. After every component of the system is installed, the
balancer tension must be adjusted to its final setting.
Increase the spring tension by turning the balancer counter-
clockwise until the rubber stop hits the balancer.
b. Add two more ”quarter-clicks” to ensure full retraction of
the balancer cable.
It’s possible the balancer tension needs to be fine-tuned after
total system is installed and a test run is done.
Balancer tuning:
Problem
:
The Grabber®
®
nozzle hits the ground after disconnection.
Solution
:
Increase the balancer tension with 1 (one) ”quarter-click”.
Problem
:
The ”swing-back” of the hosedrop after disconnection is too
extreme.
Solution
:
Decrease the balancer tension with 1 (one) ”quarter-click”.
WARNING
The balancer is delivered under tension. Be carefull
when fine tuning the balancer.