31
5. RDK
Mode
Configuration
The RDK hardware’s Processor/Local Bus is pre-configured for non-multiplexed data and address (C
Mode) Processor/Local Bus operation. It can be reconfigured for multiplexed data and address
Processor/Local Bus operation (J Mode). Several resistors configure the RDK hardware’s
Processor/Local Bus for C or J Mode. The specific resistors to install and remove for each mode are
detailed in Table 5-1. (‘X’ means installed; no ‘X’ means removed.)
Table 5-1. RDK Board Mode Configuration
Resistors
Value
C Mode
(Default)
J Mode
Mode Pins Configuration
R32
1/10w, 10K ohm, 5%
X
R33
1/10w, 10K ohm, 5%
R34
1/10w, 0 ohm, 5%
X
R35
1/10w, 0 ohm, 5%
X
X
Data/Address Pins Configuration
R74
1/10w, 0 ohm, 5%
X
R75
1/10w, 0 ohm, 5%
X
R76
1/10w, 0 ohm, 5%
X
R77
1/10w, 0 ohm, 5%
X
R84
1/10w, 0 ohm, 5%
X
R85
1/10w, 0 ohm, 5%
X
R87
1/10w, 0 ohm, 5%
X
R88
1/10w, 0 ohm, 5%
X
R93
1/10w, 0 ohm, 5%
X
R94
1/10w, 0 ohm, 5%
X
R95
1/10w, 0 ohm, 5%
X
R96
1/10w, 0 ohm, 5%
X
R97
1/10w, 0 ohm, 5%
X
R100
1/10w, 0 ohm, 5%
X
R103
1/10w, 0 ohm, 5%
X
R106
1/10w, 0 ohm, 5%
X
R108
1/10w, 0 ohm, 5%
X
R109
1/10w, 0 ohm, 5%
X
R110
1/10w, 0 ohm, 5%
X
R111
1/10w, 0 ohm, 5%
X
R112
1/10w, 0 ohm, 5%
X
R113
1/10w, 0 ohm, 5%
X
LA29/ALE
R50
1/10w, 10K, 5%
X
R51
1/10w, 4.7K ohm, 5%
X