PEX 8311RDK Hardware Reference Manual, Version 0.90
© 2005 PLX Technology, Inc. All rights reserved.
9
3.3.5
PLX Option Module Connector
The PLX Option Module Connector (J3) assumes that the Local Bus is configured for 32-bit multiplexed
address/data bus (J mode) operation. (See Section 5 - RDK Mode Configuration - for details on re-
configuring the RDK hardware for J Mode operation.) It can be used for expansion and prototyping.
Both/either a master and/or slave devices may be connected to this connector, which resides at Local
Bus address range 1000 0000 – 1FFF_FFFFh. The external arbiter in the CPLD uses CS0# to select the
POM module. Schematic sheet 6 provides the connector signal details.
The connector to mate to J3 can be purchased from AMP distributors the part number is: 6-104652-0