TECHNICAL SUPPORT: (909) 259-6001
BLSW1016
21
Installation: LIMIT SWITCH SET-UP
Limit Switch Set-Up (continued):
LIMIT SWITCH
CONNECTIONS
The Limit Switches are
pre-wired. Should the
wires become dis-
connected, use this
diagram to reconnect
them.
Fast
Slow
Slow
OPENING/CLOSING SETUP
1. Setup the limit switches manually at the
desired open and close position.
2. Allow the gate operator to run a full open
and close cycle (from limit to limit) without
interruption.
Note: During the first full open and close
cycle, the gate operator will run at low speed.
During subsequent cycles, the gate operator
will speed up at start and slow down prior to
reaching its limits.
3. Verify that the gate opens and closes to
the desired position.
Note: When slightly adjusting the open or close limit position(s), the operator will auto-
matically adapt the changes. When relearning is needed, push and hold "RESET"
button for 3 second, the machine will return to original state, and be ready for learning.
Black
Red
Gre
en
Wh
ite
Right Limit
Switch
Left Limit
Switch
BLSW1016 Manual_Layout 1 5/8/2015 5:06 PM Page 21