28
TECHNICAL SUPPORT: (909) 259-6001
BLSW1016
Installation: Selectable Features
OPEN ON POWER FAIL:
The Auto-Open feature in Platinum Access Systems Gate Operators enables the following
functionality in the event of power failure:
a. Open the gate in case of power failure (120 or 220 VAC).
b. Keep the gate at the open position as long as the there is no power.
c. Resume to normal operation when the power has been restored.
All accessories and safety devices are functional. The only function disabled is the close command.
ADVANCING LOCK SELECT:
PRIMARY/SECONDARY OPERATOR SELECT:
I
Auto-Open
To enable the Auto-Open feature: Select the
DIP switch to AUTO OP position.
ADV MLOK
To set the maglock to be engaged before the
gate reaches the close or open position:
Select the DIP switch to ADV MLOK position.
Primary/Secondary
To set the operator to Secondary: Select the
DIP switch to SECONDARY position. Recycle
power to make the new setting effective.
To set the operator to Primary: Select the DIP
switch to PRIMARY position. Recycle power
to make the new setting effective.
BLSW1016 Manual_Layout 1 5/8/2015 5:06 PM Page 28