background image

PLATINUM ACCESS SYSTEMS

1725 E. Grevillea Court, Ontario, CA  91761 
Phone: (855) 466-8686  I  Fax: (909) 923-7890

© 2013 Platinum Access Systems, Inc. All Rights Reserved.

www.PlatinumASI.com

BLSW1016 Manual_Layout 1  5/8/2015  5:07 PM  Page 36

Содержание BLSW1016

Страница 1: ...BLSW1016 BLSW1016 Manual_Layout 1 5 8 2015 5 06 PM Page 1...

Страница 2: ...ss II Class III and Class IV Safety Information Installation Inductive Loops Alarm Reset Switch Plan of Installation Electrical Limit Switches Primary Secondary Connections Loop Rack Accessory Connect...

Страница 3: ...Insure a safe and proper installation 9 QVWDOO WKLV HTXLSPHQW LQ DFFRUGDQFH ZLWK WKH 8 VSHFL FDWLRQV 10 All installation MUST have secondary protection devices against entrapment such as edge sen sor...

Страница 4: ...o obstruct the moving gate c Allow any one get close to the moving gate 12 Keep remote control or any other gate operator remote devices away from the children 13 If operator breakdown or mulfunction...

Страница 5: ...pe of ap plication b Care shall be exercised to reduce the risk of nuisance tripping such as when a vehicle trips the sensor while the gate is still c One or more non contact sensors shall be located...

Страница 6: ...te for the construction of the gate and the Usage Class of the gate RESIDENTIAL VEHICULAR GATE OPERATOR CLASS I A vehicular gate operator or system intended for use In a home of one to four single fam...

Страница 7: ...are not able to reach it and make sure it is away from all moving parts of the gate 1000 lb MAX 16 0 CLOSE STOP OPEN Location of Control Buttons Location of Control Buttons Maximum Gate Length Maximu...

Страница 8: ...cated and its wiring arranged so that the communica tion between the sensor and the gate operator is not subjected to mechanical damage Use only Miller Edge 3 sided activation type MGR20 or MDS20 to c...

Страница 9: ...es to comply with UL325 Open Position Photo Beam Device Reflector Potential Entrapment Area Consult the UL325 device installation manual for more detail information about the usage installation and ma...

Страница 10: ...ed when using a center loop See Loop Wiring Outside Inside Outside Safety Loop Center Loop Inside Safety Loop Exit Loop 5 5 5 X X 5 Gate in Open Position Even with Open Gate Outside Safety Loop Outsid...

Страница 11: ...oop Detector Wire Sand filled Saw Cut Saw Cut Asphalt Re surface New Asphalt New Slab Pour Ty wrap 1 1 4 PVC Pipe to the top of the rebar in the size and configuration of the loop i e 4ft x 8ft Then t...

Страница 12: ...ctuated in two different forms 1 The Built in Stop switch on the Control Box 2 The External Stop button within the sight of the gate away from moving parts of the gate and out of reach of children STO...

Страница 13: ...nstallation shown using the Straight Arm Secondary Extension can NOT be back driven If a back driven installation is required an Elbow Arm Secondary Extension can be used Contact Platinum Access for a...

Страница 14: ...d be at least 28 long 20 wide and 24 deep to ensure the stable operation of the operator and a minimum of 4 above level grade to avoid any flooding of the operator 3 To support the weight of the gate...

Страница 15: ...n process use C clamps or tack weld pieces STEP 3 With the clutch released manually position the gate from the completely open to the completely closed position Confirmthat the gate arm combination pr...

Страница 16: ...shipped factory adjusted The Arm Clamp must be tight enough to prevent slip page in normal operation Check the tightness of the Arm Clamp A Remove the Output Key from the Arm Clamp B Attempt to manual...

Страница 17: ...must be a single whole piece of wire Never splice two wires for the ground wire If you cut the ground wire too short break it or destroy its integrity replace it with a single wire length Prevent unn...

Страница 18: ...TION Connecting Power Connect the LIMIT harness to J14 and MOTOR CTL harness to J4 On the OPEN DIR switch Select RIGHT to open right Select LEFT to open left White Green Black Red OPEN LEFT OPEN RIGHT...

Страница 19: ...on D Move the Limit Switch Cams on the Cam Wheel to actuate each limit switch E Slightly tighten the screw on the Limit Switch Cam F Move the gate manually to the open position Repeat steps a b and c...

Страница 20: ...ut interruption Note During the first full open and close cycle the gate operator will run at low speed During subsequent cycles the gate operator will speed up at start and slow down prior to reachin...

Страница 21: ...A PSC100 NOTE Use 16 Guage Wire for runs up to 100 Conduit Shield Wire Caution Do not run Primary Secondary communication cable Model PA PSC100 in the same conduit as the power supply 120 220V cable I...

Страница 22: ...e Center Exit Center Gnd Safety Twist Wire Outside the Loop 6 Twists Foot Until Its Connection to the Loop Rack Inside Safety Loop Center Loop Outside Safety Loop Exit Loop Loop Connector Control Boar...

Страница 23: ...of the photo beam The optional PBD connector provides a controlled power supply for Photo Beam The power will be turned off when gate is in close position to save battery Option for Solar Power Input...

Страница 24: ...the gate Open Close By having the radio receiver connected as illustrated and with the Timer OFF Every command of the radio transmitter will control the gate as follow A First command opens the gate...

Страница 25: ...he gate operator to Open Stop and Close the gate The switches for Open and Close must be normally open type The switch for Stop must be normally close type They all can be using the same common ground...

Страница 26: ...ovided an external power source This will prevent damaging the battery in the event of line power failure Green Black White Red Supplied with Lock Kit 24VDC Magnetic Lock PA MAG13 Supplied with Lock K...

Страница 27: ...functional The only function disabled is the close command ADVANCING LOCK SELECT PRIMARY SECONDARY OPERATOR SELECT I Auto Open To enable the Auto Open feature Select the DIP switch to AUTO OP positio...

Страница 28: ...primary or secondary operator Instant Reversing Sensor The Obstruction Sensor needs to be adjusted to compensate for the installation and gate weight The overload adjustment is provided to set the ga...

Страница 29: ...Solar Regulator Input 24 VDC Panel 12 VDC Panels FAIL SAFE SECURE Fail Safe Secure On Fail Safe Off Fail Secure Fail Safety Input ON ON ON ON OFF OFF OFF OFF Battery Detection Normal Normal Low OFF Lo...

Страница 30: ...Check that all mounting hardware of the gate operator is properly tightened Ensure that the gate moves freely Check for corroded parts and replace if necessary Check the battery for the following Batt...

Страница 31: ...ke sure the connection is correct Connect from the receiver common pin to operator main board 28Vpin and connect the receiver 24V pin to operator main board GND pin If your connection is wrong it can...

Страница 32: ...Secondary gate operator If any input device is connected to the Secondary unit please change it to connect to the primary unit Then press Reset to rest the operators e Gates Hit Each Other Master Sla...

Страница 33: ...34 TECHNICAL SUPPORT 909 259 6001 BLSW1016 Part BLSW1016 Manual_Layout 1 5 8 2015 5 07 PM Page 34...

Страница 34: ...ESS SYSTEMS 1725 E Grevillea Court Ontario CA 91761 Phone 855 466 8686 I Fax 909 923 7890 2013 Platinum Access Systems Inc All Rights Reserved www PlatinumASI com BLSW1016 Manual_Layout 1 5 8 2015 5 0...

Отзывы: