14
TECHNICAL SUPPORT: (909) 259-6001
BLSW1016
PLAN OF INSTALLATION
Plan of Installation:
B
C
C = A + 12"
Inside
Outside
Gate in Closed Position
E
E = (L x 0
.4)
D = (L x 0
.6)
L = 87 M
aximum
with Plati
num Arm
A
F
G
ate
in
O
pe
n P
os
itio
n
D
L
The gate must be installed in a location so that enough clearance is supplied between the
gate and adjacent structures when opening and closing to reduce the risk of entrapment.
Swinging gates shall not open into public access areas.
The installation shown using the
Straight Arm Secondary Extension can
NOT be back-driven. If a back-driven
installation is required, an Elbow Arm
Secondary Extension can be used.
Contact Platinum Access for availability.
*Note: The dimensions provided are
just a guideline. Each site may have
different geometries or possibilities of
installation. The key for installation is
to have "D" longer than "E" and to
adjust the arms such that the arm is
straight at the closed position.
BLSW1016
Position
A
B
C
2
1
3
4
5
35
33
31
29
27
13.5
13.5
13.5
13.5
13.5
47
45
43
41
39
COMPACT INSTALLATION
Position
A
1
27
12
36
35
23
B
C
D
E