background image

 

 

R3 Roller Garage Door Opener 

 

 

 

 

 

 

 

INSTALLATION INSTRUCTIONS | OWNERS COPY

 

Содержание R3

Страница 1: ...1 R3 Roller Garage Door Opener INSTALLATION INSTRUCTIONS OWNERS COPY ...

Страница 2: ...of persons to follow all instructions Failure to comply with the installation instructions and the safety warnings may result in serious personal injury and or property and opener damage Please save these instructions for future reference ...

Страница 3: ...2 Product Features Page 6 3 Installation instructions Pages 7 8 4 Setting and operating Page 9 15 5 Common trouble shooting Page 16 17 6 Packing list Page 18 7 Technical data Page 18 8 Final notes Page 19 9 Important information for the user Page 19 ...

Страница 4: ... not disengage the door opener to manual operation with children persons or any other objects including motor vehicles within the doorway Wall switch or transmitter must be installed high enough and make sure children can t reach them The door opener is not intended for use by young children or infirm persons without adequate supervision Children should be supervised to ensure that they do not pla...

Страница 5: ...ctric beam must be fitted correctly and tested for operation at regular intervals Extreme caution is recommended when using auto close mode All safety rules must be followed In order for the garage door opener to sense an object obstructing under the door way some force must be exerted on the object As a result the object door and or person may suffer damage or injury If the circuit is damaged it ...

Страница 6: ...ters can be stored in the opener s memory 6 Energy efficient LED light The light will automatically on when operating and automatically off 3 minutes later after finish operating 7 Back up battery terminal available Back up battery optional 8 Auto close mode available The door will be closed automatically 1 minute after it is fully opened in default auto close setting NOTE It is compulsory to inst...

Страница 7: ...ORTANT SAFETY INSTRUCTIONS FOR INSTALLATION Warning Incorrect installation can lead to severe injury Follow this installation instruction SIDE ROOM REQUIREMENTS Fig 1 shows the minimum and recommended side room The distance between the edge of the door curtain and the inside of the bracket must be at least 40mm However for easier access it is recommended that at least 95mm is allowed 2 FIXING OF D...

Страница 8: ... hand door mounting bracket from wall 6 Remove the drive assembly from the packaging Try to rotate the drive gear by pushing on the fork Fig 6 If the gear does not rotate the manual mode has to be selected To select pull downward the manual release lever The drive gear should now rotate freely 7 Slide the drive assembly over the door axle making sure that the fork extends into and over one of the ...

Страница 9: ...ING AND OPERATING 2 PB GND PE 24V terminal 4 Battery backup terminal 6 K button same function as O S C button 1 O S C button 3 Manual release lever 5 Programming panel H Hole for battery backup connection wires ...

Страница 10: ...nstallation or 0 right installation Press SET button to confirm the setting The default setting is right hand installation 0 means right installation Press UP button Press SET button Display from 1 to 5 1 means left installation Press DOWN button Turn into 1 left installation Turn into 0 right installation Press SET button to confirm setting Please follow all setup steps from start to finish on in...

Страница 11: ...ne the final up limit position then press SET button to confirm The display will now show a 2 automatically Adjust the down limit by pressing down button Fine tuning up or down button to determine the final down limit position then press SET button The opener will operate a cycle automatically to remember the limit positions and the opening closing force If completed correctly a half 11 will be di...

Страница 12: ... times on the remote the coding light will extinguish The remote has been coded successfully Use the same method to code multiple remotes Up to 20 can be stored at any one time Press CODE button Red light turn on Light flashes 4 3 2 Deleting remotes Press the code button over 8 seconds until display shows C then it will be under standby mode All stores remotes are now deleted Press CODE button ove...

Страница 13: ... DOWN button to adjust the force The force from 1 to 9 Min force is 1 max force is 9 Press DOWN button Display 11 Press UP button Display H Press SET to confirm 4 5 2 Activating the photocell function Press DOWN button and hold on until the LED displays 11 press UP button the LED displays H photocell function is available press SET to confirm Press SET to confirm 4 5 1 The GND PE 24V connections o...

Страница 14: ... Press UP button and hold on until the LED displays Press up button once the auto close time will increase by 1 minute the maximum time is 9 minutes Press down button the auto close time decrease by 1 minute The auto close function will be turned off when LED displays 0 Press SET button to confirm The default setting for this function is 0 off NOTE The auto close is only available when door is at ...

Страница 15: ...t must use 24V DC 3 5Ah sealed lead acid battery Please open the light cover to connect the wires of battery with the battery backup terminal in the control board Fig 12 The H of Fig 11 is a hole for battery connection wires to through ...

Страница 16: ... reverses automatically when closing The moving force of the motor is set too low Increase the safety reverse force There could be an obstruction under the door Remove obstruction The door stops automatically when opening The moving force of the motor is set too low Increase the safety reverse force The operator can be controlled by O S C button but not the remote The remote light doesn t flash Th...

Страница 17: ...limit setting Left right installation error Chang the installation direction according to left right installation setting in the instruction manual 2 short beeps from buzzer means 24V DC Motor out of work The connector of motor break away the control board Please make sure well connection between motor connector and control board Motor fault Please change a new motor 3 short beeps from buzzer mean...

Страница 18: ... arm 1 Installation manual 1 Weight bar optional 2 7 TECHNICAL DATA Input voltage 200 V AC 240 V AC 50 60 HZ Controller voltage 24 V DC Max power 235W Lifting force 400N 40kgs Working circumstance 20 40 Operator limits travel 4 circles of door drum wheel Receiver type 433 92 MHZ ASK rolling code The Max height of door 4 5m ...

Страница 19: ...9 IMPORTANT INFORMATION FOR THE USER Once the opener has been installed the user must be informed about how it works and all the risks that can arise if it is used improperly The user must avoid placing himself herself in dangerous situations such as standing within the door s operating range when it is moving Do not let children play near the door and keep the remote controls out of their reach A...

Страница 20: ...20 Distributed in New Zealand by Newfield Group PO Box 11303 Christchurch New Zealand www garageace co nz 0800 600 789 ...

Отзывы: