background image

 

 

 

 

 

 

 

 

www.calimetco.com

 

9949 Hayward Way South El Monte CA 91733 

Tel: (626) 452-­­9009 

Содержание CM3-ACFP

Страница 1: ...www calimetco com 9949 Hayward Way South El Monte CA 91733 Tel 626 452 9009...

Страница 2: ...SS THE PATH OF MOVING GATE Test gate operator monthly The gate MUST reverse in contact with a rigid object of reverse when an object activates the non contact sensors After adjusting the force or limi...

Страница 3: ...nstallation of Base 1 Lay out position of 6 Anchors by measuring clearance between anchors and inside edge of gate Figure 1 2 Install underground conduits in area for conduits Figure 2 Figure 1 Figure...

Страница 4: ...3 Installation Barrier distance Figure 3 Figure 4...

Страница 5: ...4 Position Of Gate and Operator Two options for chain connections Figure 5 Rear Mount Figure 6 Front Mount...

Страница 6: ...Welding Bracket of Chain Figure 7 Correct connection of chain Figure 8 Figure 8 Follow the correct way to install chain Incorrect installation will cause malfunction of operator and potential damages...

Страница 7: ...wires power wires MUST have minimum capacity for 25 Am current 2 All operators MUST be properly grounded in order to prevent electrical charge Must use dedicated circuit for power supply 3 When power...

Страница 8: ...ove slightly to the right until it was locked in 3 Hold and push gate to desired direction B Reset pedal Only when operator has No reaction while using remote control 1 Push pedal downward from locked...

Страница 9: ...8 Entrapment Protection Safety and Exit Loop Figure 11...

Страница 10: ...9 Control Board Lay Out Figure 12...

Страница 11: ...10 Gate Travel Limit Adjustment Figure 13 Turn up or down of both wheels to adjust distance in between make gate stop at the desired position...

Страница 12: ...ress STUDY key and hold for 8 seconds watching light state flashing solid flashing setting is done All existing Self study codes have been removed Numeric Mode A First to turn SW9 key to ON position n...

Страница 13: ...ailgating system It corresponds to underground safety loop After the vehicle has cleared safe loop outside of property gate will start to close immediately without opening to limit when ON is selected...

Страница 14: ...ainboard protector box Slave Operator Activation Figure 18 1 Set SLAVE switch on SLAVE CONTROL BOARD to ON position 2 Use UL proved electric wire connect DATA and DATA from Master control board to Sla...

Страница 15: ...turning knob clockwise counter clockwise 3 Test device sensitivity every 6 months Remote Control Timer Delay Closing A Remote Control delay closing Figure 20 1 Choose time delay to activate operator...

Страница 16: ...Calimet Co Inc 9949 Hayward Way SouthE1Monte CA91733 Tel 626 452 9009 Alternate 626 482 3066 Fax 626 452 9010 Info ca1imetco com www bestirongatemotor com...

Отзывы: