11
Use Remote Control
Device
Figure 14
There are two modes to set remote control: Self--study Mode& Numeric Mode
Self--study code may be set up to 60 groups.
A.
Self--study mode corresponds to receiver in control board. Press and hold
STUDY key for 3 seconds until flashing light turn to solid bright, press any key on
remote control until STUDY light turn to flashing again, setting now is done. Repeat
above if additional code needed.
B.
Existing Codes removal. Press STUDY key and hold for 8 seconds, watching
light state: flashing--solid--flashing, setting is done. All existing Self--study codes have
been removed.
Numeric Mode
A.
First to turn SW9 key to ON position, now control board is activated.
B.
Make a combination of code. On SW8, Set an 8--digit combination to match
identical 8--digit combination on Remote Control. Note: each switch could be
placed on up, middle or low position. There is no limit for groups of combinations.
C.
On switch SW10, KEY 1 and KEY 2 are used for 2--buttom model of remote
controls. Note: if
KEY 1 code was set with BUTTON ONE on remote control; KEY 1 will NOT work with
BUTTON TWO on remote control.