INSTALLATION
Contact Sensor (Edge) Installation:
Secondary Entrapment Protection
One or more contact sensors shall be located on the inside and outside leading edge of a swing gate.
Also if the bottom edge of a swing gate is more than 6” (152mm) above the ground at any point in its
travel on or more sensors shall be located to protect from the bottom edge.
A wireless contact sensor such as one that transmits radio frequency signals to the gate
operator for entrap-ment protection functions shall be located where the transmission of the
signals are not obstructed or im-peded by building structures, natural landscaping or similar
obstruction. A wireless contact sensor shall function under the intended end-use conditions.
A hardwired contact sensor shall be located and its wiring arranged so that the communica-
tion between the sensor and the gate operator is not subjected to mechanical damage.
Use only Miller Edge 3-sided activation type MGR20 or MDS20 to comply with UL325
3-Sided Edge Sensor
3-
S
id
ed
E
dg
e
S
en
so
r
When manual operation is required:
1. Remove the Hat
2. Lift the Locking Handle.
3. Remove the Clutch Key
To reengage the gate operator:
1. Align the Clutch and the notches on the
Output Shaft.
2. Insert the Clutch Key.
3. Push down the Locking Handle.
4. Reattach the Hat.
Attention: Lock and release operations MUST
be performed with motor NOT RUNNING.
Manual Release
Locking Handle
(in Unlocked
Position)
Note: This type of installation DOES NOT reverse the gate all the way back to its limits when the photo-
beam is obstructed. This installation is only to protect against entrapment and to comply with UL325.
WARNING – To reduce the risk of severe injury or death to person, please to follow these instructions: