Swing and Slide Gate Operator UL 325 and
ASTM F2200 Site Planning Safety Checklist
Name:
Address:
City/State/ZIP:
Phone:
Email:
Please Print
ASTM F2200 Standards
Gate Construction Evaluation:
Gate Constructed with Safety in mind. ASTM F2200 Standards are followed
Component:
Result
(Circle)
Comments:
Figures (On Back)
All Gates
Gates have smooth bottom edges, no protrusions exceed 1/2” beyond base of gate
Pass
/
Fail
5
All access controls at least 6 ft. from gate
Pass
/
Fail
1,4
Barbed tape (razor wire) at least 8 ft. above grade
Pass
/
Fail
Barbed wire at least 6 ft. above grade
Pass
/
Fail
Separate pedestrian gate – out of reach of a moving gate – vehicular gate is
for automotive traffic only
Pass
/
Fail
1,4
Gate does not move on its own if disconnected from operator
Pass
/
Fail
Gates prevented from falling over if disconnected from supporting hardware
Pass
/
Fail
SWING
Distance from pivot point to column edge is less than 4 in.
Pass
/
Fail
4
Distance from open gate to wall or column greater than 16 in. or external
entrapment protection is provided
Pass
/
Fail
4
SLIDE
Roller covers on wheels
Pass
/
Fail
1
Meshing installed up to 6 ft. above grade if pickets spaced equal to or
greater than 2 1/4 in. apart
Pass
/
Fail
3
Gap between gate and fence post less than 2 1/4 in. & gap protected with safety device
Pass
/
Fail
2
Positive stops at both fully open and fully closed positions
Pass
/
Fail
1
Receiver guides recessed behind receiver post for receiver guides less than 8 ft.
Pass
/
Fail
Other:
Pass
/
Fail
© 2018 LiftMaster All Rights Reserved
300 Windsor Drive, Oak Brook, IL 60523
LMSPCLSWSL 4/18
Please Print
First & Last Name of Dealer:
Name of Dealership:
Dealership Address
(Street Address/City/State/Zip)
:
Dealer Signature:
Customer Signature:
First & Last Name of Installer:
Phone:
Installer Signature:
Satisfactory
Needs Repair/Replacement
Gate Safety Check
—
Simple steps to quickly determine if an End User’s gate operator is safe.
UL 325 Standard
Component:
Result
(Circle)
Comments:
Figures (On Back)
1. Gate Operator is approved to current UL 325 standards
(check operator label)
Pass
/
Fail
2. Proper gate warning signs attached to both sides of gate area
Pass
/
Fail
1,4
3. All entrapment zones protected by 2 safety devices/obstruction tested
1,4
Close Side
(circle two) Photo Eye
Reversing Edge
Inherent Reverse
Pass
/
Fail
Open Side
(circle two) Photo Eye
Reversing Edge
Inherent Reverse
Pass
/
Fail
Other Entrapment Areas
Pass
/
Fail
*Entrapment Zone: The location where an object can be caught or held in a position that increases the risk of injury