Chapter C - SERVICE MODE
Planmeca Compact i C-3
GENERAL ABOUT THE SERVICE MODE
Technical Manual
1.3 Navigating among the various service modes
The service modes are numbered with consecutive numbers. To move to the required service
mode, use the chair up and down keys (“C” or “D”) on the control panel. All the patient chair
control keys are now used for controlling the service mode and do not control the chair.
The current service mode number (symbol “n” followed by the current service mode number)
is shown on the display when moving around in the list.
Due to the small display, there are not enough digits to show simultaneously the service
mode number and its contents. Therefore the service mode number disappears after 1 sec-
ond, after which the current service mode setting or value is displayed.
Checking the current service mode number
When the service mode setting is shown on the display, pressing briefly either of the moving
keys (“C” or “D”) brings momentarily the number of the current service mode to the display.
The unit does not move to the next (or previous) service mode.
1.4 Changing an adjustable setting in the service mode
Some of the service mode numbers display a decimal point after the symbol “n”. These
modes have settings that can be changed. To change a setting do as follows:
a)
Move to the desired service mode as described in 1.3 “Navigating among the various service
modes”.
b)
Enter the SET-mode by pressing and holding the “S”-key until the yellow indicator light turns
on (1 or 5 seconds, depending on the service mode).
c)
Decrease the setting with the “A”-key, or increase it with the “B”-key.
d)
Exit the SET-mode by briefly pressing the S-key (the indicator light turns off). The SET-mode
is exited automatically if you scroll to a different service mode using the “C” and “D” keys.
However, any changes made to the previous service mode are stored.
NOTE
To ensure that changes made in the service mode are stored, you must exit the
service mode by using the program key. All altered settings, even if they have
an immediate effect, are lost if the power is turned off before pressing the pro-
gram key.
This behaviour can, however, be used as a “master undo”, if you for some rea-
son want to return to the previous settings. The factory presets (mode 16) are
stored immediately and cannot be un-done.
D
C
Press to move up in the list
Press to move down in the list
S
S
A
B
Press and hold until LED lights
to enter the SET mode
Exit SET mode
Increase the setting
Decrease the setting
Содержание Compact I
Страница 1: ...technical manual 10007462_23 EN...
Страница 2: ......
Страница 20: ...Chapter A GENERAL TECHNICAL DATA A 12 Planmeca Compact i EMC INFORMATION Technical Manual...
Страница 78: ...Chapter C SERVICE MODE C 50 Planmeca Compact i SERVICE MODE DETAILED DESCRIPTION Technical Manual...
Страница 110: ...Chapter E PREVENTIVE MAINTENANCE E 10 Planmeca Compact i WATER MANAGEMENT SYSTEM WMS Technical Manual...
Страница 212: ...Chapter H FOOT CONTROL H 18 Planmeca Compact i ADJUSTMENTS Technical Manual...
Страница 213: ...Planmeca Compact i I 1 Chapter Technical Manual I DIAGRAMS...
Страница 214: ...Chapter I DIAGRAMS I 2 Planmeca Compact i Technical Manual...
Страница 216: ......
Страница 218: ......
Страница 220: ......
Страница 222: ......
Страница 224: ......
Страница 226: ......
Страница 228: ......
Страница 230: ......
Страница 232: ......
Страница 234: ......
Страница 236: ......
Страница 238: ......
Страница 240: ......
Страница 242: ......
Страница 243: ......