4.10.9. Digital Signal Measurement Mode
The additional window displays the instrument settings when the digital signal
measurements are performed and the measured values. The view of this window is shown
in figure 4.43.
Figure 4.43
The frequency and modulation parameters setting panel is located in the upper part of
the window.
If you select
All TV channels
in
Plan
field, the panel will become as shown below:
In this mode you can select any channel of the current TV system. You can select the
channel using
Frequency, MHz:
or
Channel:
fields. You can set modulation
(
Modulation:
) and other parameters for the selected channel. If you set
Auto
in
Modulation:
field, the modulation parameters will be defined by the Analyzer
automatically. If you select some particular modification type, then you can must set the
required parameters of the channel.
If you select some particular channel plan in
Plan:
field, the panel will look similar to the
one represented below (selected plan in the figure is «New2»):