12
f) alphanumeric keypad allows entering text or numeric data;
g)
«ON/OFF»
switch
switches the power of the Analyzer on/off;
h)
«
12VDC
» connector provides connection to an external power source;
I)
«Serial Port»
connector provides connection to computer;
j)
«INPUT»
connector is for
the test signal input, “F”-type connector;
The controls are «
F1
», «
F2
», «
F3
», «
F4
», « », «
◄
», «
►
», « » and «
MENU/ENTER
»
keys.
Functional «Fx» keys are intended for selecting the command or mode of operation,
which is displayed in the bottom row of the screen above the corresponding key.
When operating in the main menu, « », « » keys select the rows containing the
icons corresponding to modes of operation to be selected.
For modes that contain parameters that can be edited one after another, « », « »
arrow keys are used for selecting a specific parameter.
« »
,
«
◄
»
,
«
►
»
,
« »
keys are used for editing the parameters that can take a
number of different values.
«
MENU/ENTER
» key is used for quitting the mode and returning to a previous one,
or for entering text (e.g. entry name of the logs).
4.2. Preparation for Measurements
Before you start to operate your IT-088 make sure to carefully read this Operating
Manual as well as to inspect the location of the controls and indicators of the Analyzer (see
section 4.1).
To prepare your Analyzer for operation with the external power source proceed as
follows:
a) unlock the Carrying Case and take the Analyzer and the Mains Adapter out;
b) connect the MC-088 Removable Module to the MB-08 Base Unit, if they were
stored separately;
c) connect the Mains Adapter to the connector located on the side panel of the IT-088
and then to the power source;
d) set
«On/Off»
switch located on the right side panel to “On”.
To prepare your IT-088 for operation in stand-alone mode, powered by the batteries,
proceed as follows:
а
) unlock the Carrying Case and take the IT-088 out;
b) connect the MC-088 Removable Module to MB-08 Base Unit, if they were stored
separately;
c) set
«On/Off»
switch located on the right side panel to “On”.
If the Removable Module software version differs from the software installed, then IT-
088 will start the program installation process automatically once the Analyzer is switched
on. The loading process is indicated by flashing backlight of the Analyzer screen.
CAUTION
Do not switch the power off while the software is being loaded!
This may lead to the loss of capability of loading the software onto your
Analyzer without the use of a PC.