PE6000 User Manual Description of Function Codes
177
These two parameters are used to adjust data received from the master and define the torque
reference relationship between the master and the slave.
If "b" expresses the zero offset of received data, "k" expresses the gain, and "y" expresses the
actually used data. The actually used data can be obtained based on the formula:
y = kx + b
The value y ranges from -100.00% to 100.00%.
A8-06
Point-point communication interruption
detection time
Default
1.0s
Setting Range
0.0–10.0s
It is used to set the point-point communication interruption time at which this fault is detected. If
it is set to 0, it indicates no detection.
A8-07
Master data sending cycle
Default
0.001s
Setting Range
0.001–10.000s
A8-04
Zero offset of received data (torque)
Default
0.00%
Setting Range
-100.00%–100.00%
A8-05
Gain of received data (torque)
Default
1.00
Setting Range
-10.00–10.00