Description of Function Codes PE6000 User Manual
162
receiving the stop command.
Function
Code
Parameter Name
Setting Range
Default
PC-17
Simple PLC retentive
selection
Unit's digit (Retentive upon power failure)
00
0: No
1: Yes
Ten's digit (Retentive upon stop)
0: No
1: Yes
PLC retentive upon power failure indicates that the AC drive memorizes the PLC running
moment and running frequency before power failure and will continue to run from the memorized
moment after it is powered on again. If the unit's digit is set to 0, the AC drive restarts the PLC
process after it is powered on again.
PLC retentive upon stop indicates that the AC drive records the PLC running moment and
running frequency upon stop and will continue to run from the recorded moment after it starts up
again. If the ten's digit is set to 0, the AC drive restarts the PLC process after it starts up again.
Function
Code
Parameter Name
Setting Range
Default
PC-18
Running time of simple PLC reference 0
0.0–6553.5s (h)
0.0s (h)
PC-19
Acceleration/deceleration time of simple PLC
reference 0
0–3
0
PC-20
Running time of simple PLC reference 1
0.0–6553.5s (h)
0.0s (h)
PC-21
Acceleration/deceleration time of simple PLC
reference 1
0–3
0
PC-22
Running time of simple PLC reference 2
0.0–6553.5s (h)
0.0s (h)
PC-23
Acceleration/deceleration time of simple PLC
reference 2
0–3
0
PC-24
Running time of simple PLC reference 3
0.0–6553.5s (h)
0.0s (h)
PC-25
Acceleration/deceleration time of simple PLC
reference 3
0–3
0
PC-26
Running time of simple PLC reference 4
0.0–6553.5s (h)
0.0s (h)
PC-27
Acceleration/deceleration time of simple PLC
reference 4
0–3
0
PC-28
Running time of simple PLC reference 5
0.0–6553.5s (h)
0.0s (h)