Function Code Tables PE6000 User Manual
58
Group F7: Operation Panel and Display
Function
Code
Parameter Name
Setting Range
Default
Property
P7-01
MF.K Key function
selection
0: MF.K key disabled
1: Switchover between operation panel
control and remote command control
(terminal or communication)
2: Switchover between forward rotation
and reverse rotation
3: Forward JOG
4: Reverse JOG
0
★
P7-02
STOP/RESET key
function
0: STOP/RESET key enabled only in
operation panel control
1: STOP/RESET key enabled in any
operation mode
1
☆
P7-03
LED display running
parameters 1
0000–FFFF
Bit00: Running frequency (Hz)
Bit01: Set frequency (Hz)
Bit02: Bus voltage (V)
Bit03: Output voltage (V)
Bit04: Output current (A)
Bit05: Output power (kW)
Bit06: Output torque (%)
Bit07: DI input status
Bit08: DO output status
Bit09: AI1 voltage (V)
Bit10: AI2 voltage (V)
Bit12: Count value
Bit14: Load speed display
Bit15: PID setting
1F
☆
P7-04
LED display running
parameters 2
0000–FFFF
Bit00: PID feedback
Bit01: PLC stage
Bit02: Pulse setting frequency (kHz)
Bit03: Running frequency 2 (Hz)
Bit04: Remaining running time
Bit05: AI1 voltage before correction (V)
Bit06: AI2 voltage before correction (V)
Bit08: Linear speed
Bit09: Current power-on time (Hour)
Bit10: Current running time (Min)
Bit11: Pulse setting frequency (Hz)
Bit12: Communication setting value
Bit13: Encoder feedback speed (Hz)
Bit14: Main frequency X display (Hz)
Bit15: Auxiliary frequency Y display (Hz)
0000
☆