80
HUNTER-PRO 896 Installation Guide
7.3.3
Private Dialer Fault
Make sure that:
1. The telephone line is properly connected to the LINE terminal blocks.
2. At least one private telephone number is programmed.
3. Correct telephone numbers have been entered
4. In Communication menu (section. 5.4) the “P” for telephone is programmed
with “+”.
5. In Communication/Private Dialer menu the parameters are programmed.
6. If the system is connected to an extension of a private switchboard a prefix has
been programmed.
Note
: Disarming immediately after alarm will stop the dialer. To test the dialer, arm
the system and wait for dialing
7.3.4
Incoming Calls Fault
If the system does not receive calls, make sure that:
1. In Communication menu (section. 5.4) the “P” for telephone is programmed
with “+”.
2. The programmed number of rings exceeds its limit.
3. The telephone line is properly connected to the LINE terminal blocks.
7.3.5 Tamper
TAMPER 1: Tamper 1 is open.
TAMPER 2: Tamper 2 is open.
7.3.6
Auto-Arming & Auto-Arming by Partition Faults
Make sure that:
1. Auto-arming start time is programmed (see HUNTER-PRO 896 User guide).
2. System time is correct.
3. The desired partition is programmed as so.
7.3.7
Opening Zone Causes no Alarm
Make sure that:
1. The zone is neither temporarily nor permanently bypassed.
2. The zone is programmed to the desired responses (sirens, relay, etc.)
3. The zone is programmed to only one partition.
4. The detectors are in order and installed correctly.
5. Zone sensitivity is correct.
6. Zone conditioning is correct.
7. Zone no. of pulses is correct.
8. Zone is not programmed as soak zone.