52
HUNTER-PRO 896 Installation Guide
5.4.4.2
ACK Waiting Time
Ack Wait Time:
PSTN:20 GSM:30
Set ACK time (the time in seconds which the panel waits for MS handshake signal). If
no ACK received a communication error appears. HUNTER-PRO 896 allows different
ACK waiting times for PSTN and GSM max. waiting time: 60 sec.
5.4.4.3 External
Line
External Line
_
Set a pre-number (up to two digits) if the system is connected to a switch-board.
5.4.4.4
Number of Transmissions
No. of Trans.: 5
Set the number of transmissions of the long-range radio channel for any event that is
not reported via PSTN.
.
Note
: The duration between the transmissions is 10 seconds and cannot be changed.
5.4.5
Selecting Main Monitoring Station
Set which of the following will be the main monitoring station (channel) – PSTN, GSM
(cellular) or IP network. If the system cannot communicate through the main channel,
it will try to send reports through the other two, while keep trying to call the first.
PGN
+--
Par. Main
P
PSTN
G
GSM
N
IP network (MS1 only)
5.4.6
Report Codes Formats
5.4.6.1
PSTN Report Codes
The system’s default report codes are in ContactID format (which includes PAF &
NPAF). If the FF codes are not changed, reports are Contact ID standards: Burglary,
Fire, etc. To send other codes do as follows: subtract 100 from the event number (in
ContactID) and Convert the result to hexadecimal number.
For example: to send “High Temperature” event, no. 158: 158 less 100 is 58. 58
converted to Hex. is 3A. So, by sending the code 3A you report on high temperature
(in Contact ID).
The restore code must match the alarm code.